HASTES INTRAMEDULARES - INCOMEPE
Registro cancelado em 16/05/2022 segundo a ANVISA.
Nome do produto
HASTES INTRAMEDULARES - INCOMEPE
Número de registro
10395270075
Nome técnico
Classe de risco
III
Processo
25351520872201573
País de fabricação
BRASIL
Apresentações / Modelos(190)
M8x15T40220815
M8x20T40220820
M8x25T40220825
M8x30T40220830.
Haste Intramedular Tibial Metafisária INCOMEPE Ø8 x 260 - T42000826
Ø10 x 260 - T42001026
Ø10 x 260 - T42101026
Ø10 x 280 - T42001028
Ø10 x 280 - T42101028
Ø10 x 300 - T42001030
Ø10 x 300 - T42101030
Ø10 x 320 - T42001032
Ø10 x 320 - T42101032
Ø10 x 340 - T42001034. Haste Intramedular Femoral Anterógrada INCOMEPE Ø9×340 - T40000934
Ø10 x 340 - T42101034
Ø10 x 360 - T42101036
Ø10 x 380 - T42101038
Ø10×180 - T40031018
Ø10×180 - T40041018
Ø10×200 - T40031020
Ø10×200 - T40041020
Ø10×220 - T40031022
Ø10×220 - T40041022
Ø10×240 - T40031024
Ø10×240 - T40041024
Ø10×260 - T40031026
Ø10×260 - T40041026
Ø10×280 - T40031028
Ø10×280 - T40041028
Ø10×300 - T40031030
Ø10×300 - T40041030
Ø10×320D - T40221032
Ø10×320E - T40211032
Ø10×340 - T40001034
Ø10×340×D - T40021034
Ø10×340×E - T40011034
Ø10×340D - T40221034
Ø10×340E - T40211034
Ø10×360 - T40001036
Ø10×360×D - T40021036
Ø10×360×E - T40011036
Ø10×360D - T40221036
Ø10×360E - T40211036
Ø10×380 - T40001038
Ø10×380×D – T40021038
Ø10×380×E - T40011038
Ø10×380D - T40221038
Ø10×380E - T40211038
Ø10×400 - T40001040
Ø10×400×D - T40021040
Ø10×400×E - T40011040
Ø10×400D - T40221040
Ø10×400E - T40211040
Ø10×420 - T40001042
Ø10×420×D - T40021042
Ø10×420×E - T40011042
Ø10×420D - T40221042
Ø10×420E - T40211042
Ø11 x 260 - T42101126
Ø11 x 280 - T42101128
Ø11 x 300 - T42101130
Ø11 x 320 - T42101132
Ø11 x 340 - T42101134
Ø11 x 360 - T42101136
Ø11 x 380 - T42101138
Ø11×180 - T40031118
Ø11×180 - T40041118
Ø11×200 - T40031120
Ø11×200 - T40041120
Ø11×220 - T40031122
Ø11×220 - T40041122
Ø11×240 - T40031124
Ø11×240 - T40041124
Ø11×260 - T40031126
Ø11×260 - T40041126
Ø11×280 - T40031128
Ø11×280 - T40041128
Ø11×300 - T40031130. Haste Intramedular Femoral Proximal Longa INCOMEPE Ø9×340×E - T40010934
Ø11×300 - T40041130. Haste Intramedular Femoral Sistemática INCOMEPE Ø9×320E - T40210932
Ø11×320D - T40221132
Ø11×320ET40211132
Ø11×340 - T40001134
Ø11×340 ×E - T40011134
Ø11×340×D - T40021134
Ø11×340D - T40221134
Ø11×340E - T40211134
Ø11×360 - T40001136
Ø11×360×D - T40021136
Ø11×360×E - T40011136
Ø11×360D - T40221136
Ø11×360E - T40211136
Ø11×380 - T40001138
Ø11×380×D - T40021138
Ø11×380×E - T40011138
Ø11×380D - T40221138
Ø11×380E - T40211138
Ø11×400 - T40001140
Ø11×400×D - T40021140
Ø11×400×E - T40011140
Ø11×400D - T40221140
Ø11×400E - T40211140
Ø11×420 - T40001142 Haste Intramedular Femoral Distal INCOMEPE Ø9×180- T40030918
Ø11×420×D - T40021142. Haste Intramedular Femoral Proximal Convencional INCOMEPE Ø9×180 - T40040918
Ø11×420×E - T40011142
Ø11×420D - T40221142
Ø11×420E - T40211142
Ø12 x 260 - T42101226
Ø12 x 280 - T42101228
Ø12 x 300 - T42101230
Ø12 x 320 - T42101232
Ø12 x 340 - T42101234
Ø12 x 360 - T42101236
Ø12 x 380 - T42101238
Ø12×320D - T40221232
Ø12×320E - T40211232
Ø12×340D - T40221234
Ø12×340E - T40211234
Ø12×360D - T40221236
Ø12×360E - T40211236
Ø12×380D - T40221238
Ø12×380E - T40211238
Ø12×400D - T40221240
Ø12×400E - T40211240
Ø12×420D - T40221242. Haste Intramedular Tibial Canulada INCOMEPE Ø8 x 260 - T42100826
Ø12×420E - T40211242
Ø13 x 260 - T42101326
Ø13 x 280 - T42101328
Ø13 x 300 - T42101330
Ø13 x 320 - T42101332
Ø13 x 340 - T42101334
Ø13 x 360- T42101336
Ø13 x 380 - T42101338. Parafuso Tampão INCOMEPE M8x10 - T40210810
Ø8 x 280 - T42000828
Ø8 x 280 - T42100828
Ø8 x 300 - T42000830
Ø8 x 300 - T42100830
Ø8 x 320 - T42000832
Ø8 x 320 - T42100832
Ø8 x 340 - T42000834
Ø8 x 340- T42100834
Ø8 x 360 - T42100836
Ø8 x 380 - T42100838
Ø9 x 260 - T42000926
Ø9 x 260 - T42100926
Ø9 x 280 - T42000928
Ø9 x 280 - T42100928
Ø9 x 300 - T42000930
Ø9 x 300 - T42100930
Ø9 x 320 - T42000932
Ø9 x 320 - T42100932
Ø9 x 340 - T42000934
Ø9 x 340 - T42100934
Ø9 x 360 - T42100936
Ø9 x 380 - T42100938
Ø9×200 - T40030920
Ø9×200 - T40040920
Ø9×220 - T40030922
Ø9×220 - T40040922
Ø9×240 - T40030924
Ø9×240 - T40040924
Ø9×260 - T40030926
Ø9×260 - T40040926
Ø9×280 - T40030928
Ø9×280 - T40040928
Ø9×300 - T40030930
Ø9×300 - T40040930
Ø9×320D - T40220932
Ø9×340×D – T40020934
Ø9×340D - T40220934
Ø9×340E - T40210934
Ø9×360 - T40000936
Ø9×360×D - T40020936
Ø9×360×E - T40010936
Ø9×360D - T40220936
Ø9×360E - T40210936
Ø9×380 - T40000938
Ø9×380×D - T40020938
Ø9×380×E - T40010938
Ø9×380D - T40220938
Ø9×380E - T40210938
Ø9×400 - T40000940
Ø9×400 E - T40210940
Ø9×400×D - T40020940
Ø9×400×E - T40010940
Ø9×400D - T40220940
Ø9×420 - T40000942
Ø9×420×D - T40020942
Ø9×420×E - T40010942
Ø9×420D - T40220942
Ø9×420E - T40210942
Documentos Técnicos(2)
| Petição / Protocolo | Data | Assunto | Situação |
|---|---|---|---|
| 1306451167 | 11/04/2016 | MATERIAL - Retificação – Correção pela ANVISA | Publicado deferimento |
| 0757003151Primária | 22/02/2016 | MATERIAL ORTOPEDIA - Registro de Família de Material Implantável em Ortopedia | Publicado deferimento |
MATERIAL - Retificação – Correção pela ANVISA
Publicado deferimento
MATERIAL ORTOPEDIA - Registro de Família de Material Implantável em Ortopedia
Publicado deferimento
Petição primáriaProdutos relacionados
Outros produtos de INCOMEPE INDUSTRIA DE MATERIAIS CIRURGICOS LTDA
- ACETABULO BIPOLAR INCOMEPEVENCIDO10395270022
- ACETABULO DE CHARNLEY INCOMEPEVENCIDO10395270003
- ACETABULO DE MULLER INCOMEPECANCELADO10395270012
- ACETÁBULOS PARA ARTROPLASTIA DE QUADRIL - INCOMEPECANCELADO10395270069
- AGULHA DE VERESS UNIMICROCANCELADO10395270088
- ASPIRADORES INCOMEPE - ASPLASSCANCELADO10395270059
Faça seu cadastro grátis e consulte sem limite